คุณสมบัติสินค้า:

BELIMO PMBUP-MFT-T ,Nominal voltage : AC 24...240 V / DC 24...125 V ,Nominal voltage frequency : 50/60 Hz ,Nominal voltage range : AC 19.2...264 V / DC 19.2...137.5 V ,Power consumption in operation : 20 W ,Power consumption in rest position : 6 W ,Transformer sizing : with 24 V 20 VA / with 240 V 52 VA ,Torque motor : 1400 in-lb [160 Nm] ,holding torque : 50 Nm ,Operating range Y : 2...10 V ,Operating range Y note : 4...20 mA ,Direction of motion motor : reversible with app ,Ambient temperature : -22...122°F [-30...50°C] ,Storage temperature : -40...176°F [-40...80°C] ,Weight : 13 lb [5.9 kg]

หมวดหมู่ : PRODUCTS ELECTRICAL BELIMO NON FAIL-SAFE ACTUATORS

แบรนด์ : BELIMO distributor

Share

ผู้จำหน่าย Non Fail-Safe Actuators ยี่ห้อ BELIMO รุ่น PMBUP-MFT-T ราคาถูก นำเข้าตรงจากโรงงานผลิต Damper Actuator, 1400 in-lb [160 Nm], Non fail-safe, AC 24...240 V / DC 24...125 V, 2...10 V, 2x SPDT, terminals, Direction Of Motion Motor : reversible with app ตัวแทนจำหน่ายและนำเข้า สินค้าอุตสาหกรรมในประเทศไทย

BELIMO PMBUP-MFT-T Basic Non Fail-Safe multifunction technology actuator for controlling dampers in typical commercial HVAC applications.

• Torque motor 1400 in-lb [160 Nm]
• Nominal voltage AC 24...240 V / DC 24...125 V
• Control MFT/programmable
• Position feedback 2...10 V
• 2 x SPDT
• NEMA 4X

Technical data

Electrical data
Nominal voltage
AC 24...240 V / DC 24...125 V
Nominal voltage frequency50/60 Hz
Nominal voltage rangeAC 19.2...264 V / DC 19.2...137.5 V
Power consumption in operation20 W
Power consumption in rest position6 W
Transformer sizingwith 24 V 20 VA / with 240 V 52 VA
Auxiliary switch
2 x SPDT, 1 mA...3 A (0.5 A inductive), DC 5
V...AC 250 V (II, reinforced insulation), 1 x 10° /
1 x 0...90° (default setting 85°)
Switching capacity auxiliary switch1 mA...3 A (0.5 A inductive), DC 5 V...AC 250 V
(II, reinforced insulation)
Electrical ConnectionTerminal blocks, (PE) Ground-Screw
Overload Protectionelectronic throughout 0...95° rotation


Data bus communication
Communicative control
BACnet MS/TP
Modbus RTU
MP-Bus


Functional data
Torque motor
1400 in-lb [160 Nm]
holding torque50 Nm
Operating range Y2...10 V
Operating range Y note4...20 mA
Input impedance100 kΩ for 2...10 V (0.1 mA), 500 Ω for 4...20
mA, 1500 Ω for On/Off
Operating range Y variableStart point 0.5...30 V
End point 2.5...32 V
Operating modes optional
variable (VDC, on/off, floating point)
Position feedback U2...10 V
Position feedback U noteMax. 0.5 mA
Position feedback U variableVDC variable
Direction of motion motorreversible with app
Manual override7 mm hex crank, supplied
Angle of rotation95°
Running Time (Motor)35 s / 90°
Running time motor variable30...120 s
Noise level, motor68 dB(A)
Position indicationintegral pointer


Safety data
Power source UL 
Class 2 Supply
Degree of protection IEC/ENIP66/67
Degree of protection NEMA/ULNEMA 4X
Enclosure
UL Enclosure Type 4X
Agency ListingcULus acc. to UL60730-1A/-2-14, CAN/CSA
E60730-1:02, CE acc. to 2014/30/EU and 2014/35/EU
Quality StandardISO 9001
Ambient humidityMax. 100% RH
Ambient temperature-22...122°F [-30...50°C]
Storage temperature-40...176°F [-40...80°C]
Weight13 lb [5.9 kg]
Materials Housing materialDie cast aluminium and plastic casing


Product features

Application
• PMB series damper actuators are designed to accommodate a mounting bracket and coupler or linkage for remote linkage connection. A visual position indicator shows the actuators position through-out its stroke. For outdoor applications, the installed actuator must be mounted with the actuator at or above horizontal. For indoor applications the actuator can be in any position including upside down.

Operation
• The PMB series provides 95° of rotation and a visual indicator shows the position of the damper actuator. The PMB series actuator uses a low power consumption brushless DC motor and is electronically protected against overload. A universal power supply is furnished to connect supply voltage in the range of AC 24...240 V and DC 24...125 V. Included is a smart heater with thermostat to eliminate condensation. Two auxiliary switches are provided; one set at 12.5° open and the other is field adjustable. Running time is field adjustable from 30...120 seconds by using the Near Field Communication (NFC) app and a smart phone.

• †Use 60°C/75°C copper wire size range 12...28 AWG, stranded or solid. Use flexible metal conduit. Push the listed conduit fitting device over the actuator’s cable to butt against the enclosure. Screw in conduit connector. Jacket the actuators input wiring with listed flexible conduit. Properly terminate the conduit in a suitable junction box. Rated impluse Voltage 4000 V. Type of action 1. Control pollution degree 3.